Location of the sheet
-
Consult the sections
Electric cable size,Installation proposal
and
-
The following transport fixtures, painted red, must be removed:
• Bolts (1)
• Bushes (2)
-
Check that the electrical connections correspond to the applicable codes and that all wires are
clamped tight to their terminals.
The installation must be earthed and protected against short circuits by fuses of the inert type in all
phases. An isolating switch must be installed near the compressor.
-
Check transformer (T1) for correct connection.
For Full-Feature units except for voltages 230 V and 400 V + N: check transformer (T3) for correct
connection.
Check the settings of drive motor overload relay (F21).
Check that the motor overload relay is set for manual resetting.
-
Fit air outlet valve (AV); see section
for the location of the valve.
Close the valve.
Connect the air net to the valve.
On compressors equipped with a dryer bypass, fit the air outlet valve to the dryer bypass pipe.
-
Connect the condensate drain outlet(s) to a drain collector.
See section
-
For compressors with a DD or a DD and PD filter connect the automatic drain of the filters to a
suitable drain collector.
-
Check the oil level. See section Oil and oil filter change.
-
Provide labels, warning the operator that:
• The compressor may automatically restart after voltage failure (if activated, consult Atlas
Copco).
• The compressor is automatically controlled and may be restarted automatically.
-
Affix sheet (5) explaining the procedure for checking the motor rotation direction to the cooling air
outlet of the compressor. Consult section Dimension drawings.
Switch on the voltage. Start the compressor and stop it immediately. Check the rotation direction of
drive motor (M1) while the motor is coasting to a stop.
Check the motor rotation of the motor using sheet (5). If the motor rotation direction is correct, the
label on the top grating will be blown upwards. If the sheet remains in place, the rotation direction is
incorrect.
If the rotation direction of the drive motor is incorrect, open the isolating switch and reverse two
incoming electric lines.
Incorrect rotation direction of the drive motor may cause damage to the compressor.
-
On compressors equipped with an Elektronikon I regulator, check the settings; see section
.
-
Start and run the compressor for a few minutes. Check that the compressor operates normally.
Instruction book
API451763
63