Checking the oil level
When the automatic operation LED (8) is lit, the regulator is automatically controlling the
compressor, i.e. loading, unloading, stopping of the motors and restarting!
Control panel, Elektronikon I
Regularly check the oil level. To do this, press the stop button (9). Three minutes after stopping,
sight-glass (Gl) should be between 1/4 and 3/4 full.
If the oil level is too low, press the emergency stop button (10), close the air outlet valve and
open (if provided) the manual condensate drains. See section
and section
for location of the outlet valve and the water drain. Next, depressurise the oil
system by unscrewing oil filler plug (FC) one turn and wait a few minutes. Remove the plug and
top up oil, until the sight-glass is full. Fit and tighten the plug (FC).
Position of oil level sight-glass on GA 15 up to GA 22
Unlock the emergency stop button (10) and press the reset key (14) before restarting.
Instruction book
API451763
65