Step
Action
-
Switch off the voltage and disconnect the compressor from the mains.
-
Unscrew the oil filler plug only one turn to permit any pressure in the system to escape.
-
Shut off and depressurise the part of the air net which is connected to the outlet valve.
Disconnect the compressor air outlet pipe from the air net.
-
Drain the oil.
-
Drain the condensate circuit and disconnect the condensate piping from the condensate net.
Instruction book
68
API451763