General
When servicing, replace all removed gaskets, O-rings and washers.
Intervals
The local Atlas Copco Customer Centre may overrule the maintenance schedule, especially the
service intervals, depending on the environmental and working conditions of the compressor.
The longer interval checks must also include the shorter interval checks.
Service actions for compressors with Elektronikon I
Besides the daily and 3-monthly checks, the service operations are grouped in time intervals
(running hours). The regulator has a programmable service timer. A service warning will appear
when the service timer has reached the programmed time interval; see section
.
In this case, check the running hours. Carry out the service operations corresponding to the
running hours as specified in the schedule below. Reset the service timer after servicing; see
section
Calling up/resetting service timer
Preventive maintenance schedule
Daily and 3-monthly check list
Period
Action
Daily
Check oil level.
Check readings on display.
Check that condensate is discharged during loading.
Drain condensate.
Check air filter service indicator.
Check the service indicator on the DDx and PDx filters (if provided).
3-monthly (1)
Check coolers, clean if necessary.
Remove the air filter element. Clean using an air jet and inspect. Replace damaged or
heavily contaminated elements.
Check the filter element of the electric cabinet (where applicable). Replace if necessary
On Full-Feature units: Check condenser of dryer and clean if necessary.
Yearly
Yearly inspect the air receiver. Minimum wall thickness as specified in the instruction
book must be respected. Local regulations remain applicable if they are more strict.
(1): More frequently when operating in a dusty atmosphere.