Procedure
Oil system components of GA 15 up to GA 22
1. Run the compressor until warm. Stop the compressor. Close the air outlet valve and switch
off the voltage. Depressurise the compressor by opening manual drain valve(s) (Dm, Dm1).
Wait a few minutes and depressurise the air receiver/oil tank (OT) by unscrewing oil filler
plug (FC) just one turn to permit any pressure in the system to escape.
2. Remove oil drain plug (DP1) and drain the oil by opening valve (Vd). Also remove the drain
plug on flexible (1) near the element outlet. To drain the oil in the oil cooler, remove the vent
plug on the oil cooler. As an alternative, it is also possible to loosen the flexible hoses to the
oil cooler to allow air to enter the cooler. Close the drain valve (Vd) and fit the plugs after
draining.
3. Collect the oil and deliver it to the local collection service. Refit and tighten the drain and
vent plugs after draining.
4. Remove the oil filter (OF). Clean the seat on the manifold. Oil the gasket of the new filter
and screw it into place. Tighten firmly by hand.
5. Remove filler plug (FC).
Insert an elbow coupling in the filler plug (FC) for easy filling. Fill the air receiver/oil tank
(OT) with oil until the level reaches the middle of sight-glass (Gl).
Take care that no dirt drops into the system. Refit and tighten filler plug (FC).
6. Run the compressor loaded for a few minutes. Stop the compressor and wait a few minutes
to allow the oil to settle.
7. Depressurise the system by unscrewing filler plug (FC) just one turn to permit any pressure
in the system to escape. Remove the plug.
Add oil until the sight-glass (Gl) is 3/4 full.
Take care that no dirt enters the system. Tighten the filler plug.
8. Reset the service warning after carrying out all service actions in the relevant Service Plan:
For compressors equipped with an Elektronikon I regulator, see section
.
Instruction book
76
API451763