9.4
Dryer switches
General
The regulating and safety devices are factory-adjusted to give optimum performance of the dryer.
Do not alter the setting of any of the devices.
9.5
Reference conditions and limitations
Reference conditions
Air inlet pressure (absolute)
bar
1
Air inlet temperature
˚C
20
Relative humidity
%
0
Working pressure
See section Compressor data
Limits
Maximum working pressure
See section compressor data
Minimum working pressure
bar
4
Maximum air inlet temperature
˚C
46
Minimum ambient temperature
˚C
0
9.6
Compressor data for GA 15 up to GA 22
Reference conditions
All data specified below apply under reference conditions, see section
GA 18
125 psi
Frequency
Hz
60
Maximum (unloading) pressure
bar(e)
9.1
Maximum (unloading) pressure, Full-Feature units
bar(e)
8.85
Nominal working pressure
bar(e)
8.6
Pressure drop over dryer, Full-Feature units
bar(e)
0.2
Motor shaft speed
r/min
3550
Set point, thermostatic valve
˚C
40
Temperature of air leaving outlet valve (approx.)
˚C
28
Instruction book
API451763
85