The screen shows that the compressor is running loaded (the horizontal arrow flashes) and that
the outlet pressure is 6.8 bar(e).
Always consult Atlas Copco if <test> appears on the display.
Scrolling through all screens.
3.6
Shut-down warning
Description
A shut-down warning will appear in the event of:
• Too high a temperature at the outlet of the compressor element
• Too high a dew-point temperature for Full-Feature compressors
Compressor element outlet temperature
• If the outlet temperature of the compressor element exceeds the shut-down warning level
(110 ˚C / 230 ˚F), alarm LED (4) will light up and the related pictograph will appear flashing.
Main screen with warning element outlet temperature
flashing
bar
6.6
• Press arrow key (3), the actual compressor element temperature appears.
Instruction book
30
API451763