Pb.1
• Press key (2) to modify the active pressure band. Press enter key (1) to confirm or reset key
to cancel.
3.21 Calling up/modifying service timer setting
Control panel
Starting from the Main screen:
bar
6.6
• Press arrow key (2) until <P.05> is shown and then press enter key (1): the setting of the
service timer is shown in <hrs> (hours) or <x1000 hrs>(hours x 1000). Example: <4000 hrs>
means the timer is set at 4000 running hours.
• Press enter key (1) to modify this value (a password may be required), the value blinks. Use
arrow keys (2 and 3) to modify this setting.
• Press enter key (1) to program the new value and to return to the parameter screens.