4.4
Pictographs
Pictographs GA 15 up to GA 22
Reference
Designation
1
Warning: before connecting compressor electrically, consult Instruction book for motor
rotation direction
2
Torques for steel (Fe) or brass (CuZn) bolts
3
Warning: suction
4
Lightly oil gasket of oil filter, screw filter on and tighten by hand (approx. half a turn)
5
Consult the instruction book before carrying out maintenance
6
Warning: voltage
7
Warning: hot parts
8
Lock all doors of the bodywork before starting.
• If the sheet is pulled downwards: stop the compressor and switch off the voltage.
• Reverse two incoming lines. Repeat the previous step.
• If the sheet is blown away the motor rotation is correct.
9
Manual condensate drain
10
Automatic condensate drain
11
Warning: switch off the voltage and depressurise compressor before repairing
12
Warning: disconnect electrical supply before opening
Instruction book
API451763
59