9
Technical data
9.1
Readings on display
Elektronikon I regulator
Important
The readings mentioned below are valid under the reference conditions (see section
Reference conditions and limitations
).
Reference
Reading
Air outlet pressure
Fluctuates between programmed unloading and loading pressures.
Compressor element
outlet temperature
55-65 ˚C (99-117 ˚F) above cooling air temperature.
Dew point temperature
For GA 15 up to GA 22 with built-in dryer: see section
.
9.2
Electric cable size and main fuses
Important
• The voltage on the compressor terminals must not deviate more than 10% of the
nominal voltage.
It is however highly recommended to keep the voltage drop over the supply cables at
nominal current below 5% of the nominal voltage (IEC 60204-1). If cables are grouped
together with other power cables, it may be necessary to use cables of a larger size
than those calculated for the standard operating conditions.
• Use the original cable entry. See section Dimension drawings.
To preserve the protection degree of the electric cubicle and to protect its
components from dust from the environment, it is mandatory to use a proper
cable gland when connecting the supply cable to the compressor.
• Local regulations remain applicable if they are stricter than the values proposed
below.