Industrial Air Division
9
2920 5997 03
4 Maintenance
O-rings, washers. Consult Atlas Copco for available maintenance
kits.
The "longer interval" checks must also include the "shorter
interval" checks.
4.1 Preventive maintenance schedule
The schedule contains a summary of the maintenance instructions.
Read the respective section before taking maintenance measures.
When servicing, replace all disengaged packings, e.g. gaskets,
Period 1)
Running
Operation
Consult
See
Preventive
hours 1)
section
note
main-
tenance
kit No.
Daily
------
Check oil level
(not on LEN)
3.2
1
--
Weekly
------
Drain condensate from air receiver by opening drain cock (10-Figs. 1)
--
--
--
Monthly
------
Operate safety valve by turning its knurled cap or by lifting its central
plunger with a screwdriver
--
2
--
"
------
Check that regulating system operates properly
--
--
--
"
------
Inspect air filter. Replace if necessary
5.3
4
2-Fig. 4
3-monthly
------
Clean unit. Remove dirt from cooling fins by air jet
--
3
--
Yearly
------
Test safety valve
5.5
--
--
"
------
If provided, test relief valve
5.6
--
--
"
400
On LE/LT9/12,
replace air filter
5.3
4
2-Fig. 4
"
500
On LE/LT7/8,
replace air filter
5.3
4
2-Fig. 4
"
700
On LE/LT5/6,
replace air filter
5.3
4
2-Fig. 4
"
1000
Change muffler element
on LE/LT7 up to -12 and LEN
--
--
2-Fig. 4
"
1000
Check tension of transmission belt(s) (if equipped with)
--
5
--
"
2000
Change oil
if mineral oil is used (not on LEN)
4.2
--
--
"
2000
Inspect for carbon deposits in air receiver; clean if necessary
--
--
--
2-yearly
3000
Change oil
if Atlas Copco approved P.A.O. oil is used (not on LEN)
4.2
--
5-Fig. 4
-----
3000 to
Change check valve
on LE/LT5/6
or unloader
4000
on LE/LT7 up to -12 and LEN
5.1
--
3,4-Fig. 4
-----
4000
Change valves. For possible earlier replacement consult section 5.2
5.2
--
1-Fig. 4
1) Whichever interval comes first
. The local Sales Company may overrule the maintenance schedule,
especially the service
intervals,
depending upon the environmental and working conditions of the compressor.
Remark
For partial or complete overhaul, service kits, exchange compressors, etc. are available. Consult Atlas Copco.
Notes
1. Maintain the level in the lower half of the sight-glass.
2. Always wear gloves.
3. Wear safety glasses.
4. For normal operation in clean surroundings. More frequently when operating in dusty environment.
5. Correct adjustment is obtained when each V-belt can be pushed inwards 15 mm per m distance between the two pulley centres when
a force of 20 N is exerted midway.
Summary of Contents for LE11
Page 22: ...IndustrialAirDivision 2920 5997 03 22 Fig 15 LE7 7N 8 8C LT7 8 730 Power Pack ...
Page 23: ...IndustrialAirDivision 23 2920 5997 03 Fig 16 LE9 9N 11 12 LT9 11 12 930 1230 Power Pack ...
Page 24: ...IndustrialAirDivision 2920 5997 03 24 Fig 17 LE5 6 6C LT5 6 Complete Unit ...
Page 25: ...IndustrialAirDivision 25 2920 5997 03 Fig 18 LE7 7N 8 8C LT7 8 Complete Unit ...
Page 26: ...IndustrialAirDivision 2920 5997 03 26 Fig 19 LE9 9N 11 12 LT9 11 12 Complete Unit ...
Page 28: ...IndustrialAirDivision 2920 5997 03 28 Fig 21 LE LT7 8 9 11 12 Pack ...