2920 1257 04
8
Instruction book
Fig. 1.12 Air flow of LE Trolley and regulating system of LE/LF/LT Trolley
AF
Air filter
AR
Air receiver
AV
Air outlet valve
AV1/2 Air outlet valves
CV
Check valve
Dm
Condensate drain valve
DP
Oil drain plug
FC
Oil filler cap
FN
Fan
Gp
Air pressure gauge
M
Motor
MDR Air pressure switch
PD
Pulsation damper
RV
Pilot valve
SG
Oil level sight-glass
SV
Safety valve
UA
Unloader
UV
Unloading valve
Y1
Loading solenoid valve
1
Air inlet silencer
2
Pressure release valve
3
Cylinder
4
Cooler
5
On/off switch
6
Cooling pipe
7
LP cylinder
8
HP cylinder
9
Blow-off silencer
10
Intercooler
11
Electric cabinet
12
Plunger
13
Spring
14
Pressure regulator
Figs. 1.10 up to 1.12 Air flow and regulating systems
1.3.3 LE/LF/LT Trolley (Fig. 1.12)
The regulating system includes:
-
Pilot valve (RV)
-
Unloader (UA) with integrated check valve (CV)
-
Electric cabinet (11) (only on electric motor driven Trolley
compressors)
Operation
Pilot valve (RV) opens and closes at pre-set pressures. During
loaded operation, pilot valve (RV) is closed preventing the
compressed air from flowing to unloader (UA).
When the pressure in the pulsation dampers (PD) reaches the
pre-set maximum pressure, pilot valve (RV) will open.
Summary of Contents for LE110
Page 11: ...2920 1257 04 11 Instruction book Fig 2 2 Dimension drawing LE LT55 75 and LF40 55 Power Pack ...
Page 19: ...2920 1257 04 19 Instruction book Fig 2 10 Dimension drawing LE LT15 up to 40 Unsilenced Pack ...
Page 21: ...2920 1257 04 21 Instruction book Fig 2 12 Dimension drawing LE LT15 up to 150 with CD dryer ...