36
2920 7090 00
Instruction book
Reference
Designation
6
Manual condensate drain
7
Hole, 15 x 25 (3X)
8
Receiver
9
Cooling air inlet
10
Motor cooling air inlet
11
Compressed air outlet
12
Compressor cooling air and air inlet
13
For dismantling air filter
14
Compressor air outlet with flexible (2 meters)
15
Electric cable entry (on rear side)
16
Air outlet
19
Manual condensate drain
3.2 Installation
instruction
Install the unit in an area where the noise levels do not cause inconvenience and adequate
ventilation is available for cooling purposes.
Before commencing installation, check that the electrical data on the compressor
specification plate/s are compatible with the local power supply. Before connecting, the
electricity, ensure that the power supply is off and correctly isolated.
The electrical power supplied to the compressor unit must be connected by a qualified
electrician in accordance with the wiring diagram supplied with the plant. All wiring must be in
accordance with IEE regulations. Cable sizes given in section. Electric data are
recommendations only.
Installation proposal for tank-mounted unit (90 l receiver)
Summary of Contents for LF 10
Page 1: ...Atlas Copco Industrial aluminium piston compressor LF 2 LF 3 LF 5 LF 7 LF 10 Instruction book ...
Page 2: ......
Page 12: ...10 2920 7090 00 Instruction book Power Pack with unloading valve Base mounted ...
Page 18: ...16 2920 7090 00 Instruction book Air flow and regulating system with DOL starter ...
Page 19: ...2920 7090 00 17 Instruction book Air flow and regulating system with Y D starter ...
Page 20: ...18 2920 7090 00 Instruction book Air flow and regulating system of trolley ...
Page 72: ......
Page 73: ......
Page 74: ......