2920 7090 00
49
Instruction book
5 Maintenance
5.1 Petrol engine maintenance
Consult the engine "Owner's manual".
5.2 Preventive maintenance schedule
The schedule contains a summary of the maintenance instructions. Read the respective
section before taking maintenance measures.
When servicing, replace all disengaged packing components, e.g. gaskets, O-rings,
washers. The "longer interval" checks must also include the "shorter interval" checks.
Period Running
Hours
Operation Consult
Section
See notes
below table
Preventive
maintenance kit
Daily
Drain
condensate
from air
receiver or
pulsation
damper.
Air receiver
instructions
- -
6-monthly
Test
safety
valve
Safety valve
Relief valve
1
6-monthly
Inspect
air
filter
Air
filter
2/3
2
Yearly
500
On LF 10,
replace air filter
Air filter
2
Yearly
600
On LF 5 and
LF 7, replace
air filter
Air filter
2
Yearly
800
On LF 1 and
LF 3, replace
air filter
Air filter
2
Yearly 2000
Change
blow
off silencer, If
provided
- -
2
7500 Replace
valve
discs.
Valves -
1
Notes:
1.
Wear gloves and safety glasses.
2.
For normal operation in clean surroundings. More frequently when operating in a dusty
environment.
3.
In a dusty environment, a heavy-duty filter (available as an option) is essential.
Preventive maintenance schedule Full Feature units
Only applicable on the refrigerant dryer.
Summary of Contents for LF 10
Page 1: ...Atlas Copco Industrial aluminium piston compressor LF 2 LF 3 LF 5 LF 7 LF 10 Instruction book ...
Page 2: ......
Page 12: ...10 2920 7090 00 Instruction book Power Pack with unloading valve Base mounted ...
Page 18: ...16 2920 7090 00 Instruction book Air flow and regulating system with DOL starter ...
Page 19: ...2920 7090 00 17 Instruction book Air flow and regulating system with Y D starter ...
Page 20: ...18 2920 7090 00 Instruction book Air flow and regulating system of trolley ...
Page 72: ......
Page 73: ......
Page 74: ......