Step
Action
1
Install the compressor, see sections
and
.
2
Stick labels near the control panel to warn the operator that:
• the compressor may start automatically after a voltage failure
• the compressor is automatically started and stopped
• the compressor may be remotely controlled
3
A number of VCI (Volatile Corrosion Inhibitor) plates are provided inside the bodywork to
protect the compressor against corrosion. Remove the plates.
4
For initial start-up (or if the compressor has not run for the past 6 months) it is required
to improve the lubrication of the compressor element before starting. Fill up the
compressor element as described in section
5
Check that the compressor is filled with oil; the pointer of the oil level indicator should be
in the green range.
Protection during transport
Transport fixtures
Instruction book
APF219617
57