Start up
Manual condensate drain valve
Step
Action
1
Close the manual condensate drain valve (3) (see also section
2
Switch on the voltage.
3
Start the compressor and stop it immediately. Check the rotation direction of the drive
motor while the motor is coasting to a stop. To determine the rotation direction of the
motor, look at the fan through the grating at the non-drive end of the motor. The correct
rotation direction is indicated by an arrow on the gear casing.
4
If the rotation direction is wrong, press the emergency stop button, switch off the voltage
and reverse two incoming electric lines.
5
Run the compressor for a few minutes and check that it is operating normally.
5.2
Before starting
Warning
The operator must apply all relevant
.
If the water system was drained, make sure that the drain valves are closed.
Instruction book
APF219617
59