Multiple shut-down
If there are multiple sequential failures with short time intervals on a specific shut-down functionality,
consult your Atlas Copco Customer Centre.
Excessive oil consumption
Have the compressor inspected by your Atlas Copco Customer Centre.
Condition
Fault
Remedy
Condensate is not discharged from
condensate trap during loading.
Discharge pipe of condensate
trap clogged.
Check and correct as necessary.
Float valve of condensate traps
malfunctioning.
Remove float valve assembly,
clean and check.
Condition
Fault
Remedy
Compressor air delivery or pressure
below normal.
Air consumption exceeds air
delivery of compressor.
Check equipment connected.
Choked air filters.
Replace filters.
Air leakage.
Check and correct.
Condition
Fault
Remedy
Compressor element outlet
temperature or delivery air
temperature above normal.
Oil level too low.
Check and correct.
Oil coolers clogged.
After cooler clogged.
Cooling water temperature too
high or flow too low.
Increase water flow and check
temperature.
Restriction in cooling water
system due to dirt or formation of
scale.
Consult your Atlas Copco
Customer Centre.