9
Technical data
9.1
Safety valve
Warning
Stop the compressor and switch off the voltage. The operator must apply all relevant
Never run the compressor without safety valves.
No adjustments are allowed.
Testing
The valve can be tested on a separate compressed air line.
Consult your Atlas Copco Customer Centre if the valve does not open at the correct pressure
(see section
9.2
Settings for overload relay and fuses
Model
Power (kW) Voltage (V) Nominal current
of main motor
(A)
F21 (A)
MAS 200
227
440
359
207
MAS 200
230
480
341
197
9.3
Settings of circuit breakers
Circuit breaker
Setting (A)
Q1
2.5
Q2
0.5
Instruction book
88
APF219617