Control panel
Step
Action
1
Switch on the voltage. Voltage on LED (8) lights up.
2
Close the condensate drain valves (see section
).
3
Open the air outlet valve.
4
Check the oil level indicator. The pointer should be in the green or orange range.
5
Open the water shut-off valves (if installed) and the water flow regulating valves.
5.3
Start Request (function)
Function
Upon a start command (either local or remote) the automatic operation contact will close. This
signal will be used by the customer to start a generator. A feedback signal from the generator
(closed = ready) is connected to an additional digital input on the Elektronikon module
(programmed as permissive start function). When this input is OK within 60 seconds, the unit will
start.
Contact connected between 1X6: 53-63
At standstill:
• Start Request contact closed: compressor can start - no general warning
• Start Request contact open: compressor will NOT start - general warning
--> general warning disappears when contact closes
Pressing the start button (local or remote):
• Start Request contact closed: Automatic Operation contact closes and compressor starts
immediately
• Start Request contact open: Automatic Operation contact closes and compressor waits until
Start Request is closed - general warning