Working pressure 10 bar(e) (145.04 psig).
The minimum allowable temperature at the outlet of the compressor elements is 68 ºC (154.4 °F).
Regulate the cooling water flow to obtain a temperature between 70 and approx. 75 ºC (158 and
approx. 167 °F) at the outlet of the compressor elements.
Attention
• For optimum operation, the cooling water outlet temperature must never exceed the max.
value.
• Consult Atlas Copco if condensate should be formed during frequent unloading periods.
Manual restarting
In automatic operation, the regulator limits the number of motor starts.
Observe an interval of minimum 6 minutes between each manual start.
5.5
During operation
Warning
The operator must apply all relevant
.
The operator should immediately stop the machine in case of oil leaks internally in the
machine as well as externally and consult a competent technician to resolve the cause.
The machine should not be restarted before the problem has been remedied
Control panel
1. When the automatic operation LED (7) is lit, the starting and stopping of the motor is
controlled automatically.
2. Check the readings on display (1).
3. To unload the compressor manually, select Unload on the display using the cursor keys (12)
and press the enter key (10).
Instruction book
APF219617
63