Control panel
Reference
Name
1
Press stop button (13). LED (7) goes out. The compressor will run unloaded for 3
seconds and then stops.
2
To stop the compressor in case of emergency, press the emergency stop button. Alarm
LED (4) starts flashing. After remedying the trouble, unlock the emergency stop button
by pulling it out.
3
Close the air outlet valve.
4
Open the condensate drain valves.
5
If the compressor is installed in a room where freezing temperatures are expected, drain
the cooling system by opening the drain valves in the water inlet and outlet pipes
(customer's installation).
6
Switch off the voltage.
5.9
Taking out of operation
Disconnecting the compressor
At the end of the service life of the compressor, proceed as follows:
Step
Action
1
Stop the compressor and close the air outlet valve.
2
Switch off the voltage.
Disconnect the compressor from the mains.
3
Depressurize the compressor by opening the condensate drain valve and loosening the
oil filler plug one turn.
4
Shut off and depressurize the part of the air net which is connected to the outlet valve.
Disconnect the compressor air outlet pipe from the air net.
5
Drain the oil and condensate circuits.
Drain the water circuits.
6
Disconnect the compressor condensate piping from the condensate drain net.
Instruction book
66
APF219617