Procedure
Step
Action
1
Remove the filter elements. Take care that no dirt drops into the filter chamber.
2
Clean and inspect the element sealing surface of the filter chamber.
3
Install the new or cleaned filters. Never install damaged or clogged filters.
4
Switch on the voltage, unlock the emergency stop button, open the air outlet valve and
reset the air filter service warning.
7.2
Coolers
Cleaning the coolers
Stop the compressor, press the emergency stop button and switch off the voltage. The
operator must apply all relevant
.
Procedure
Keep the coolers clean to maintain the cooling efficiency.
If it should be necessary to wash the coolers with a cleaning agent, consult Atlas Copco
Customer Centre.
7.3
Oil separator element
Stop the compressor, press the emergency stop button and switch off the voltage. Close
the air outlet valve and open the manual condensate drain valve. The operator must
apply all relevant
.
Procedure
The oil separator element is located inside of the air receiver.
The separator element can be changed if the cover of the air receiver is moved.
Always renew both O-rings.