16
ORV 10 - ORV 12 - ORX 10 - ORX 12
2.8
E
LECTRICAL
SYSTEM
Fig. 2.5
Typical Customer Installation for mechanically controlled diesel engine
G10:
Battery
M10:
Starter Motor
G20:
Battery
PS10:
Pressure Switch - Oil Pressure Protection
G30:
Alternator
S10:
Switch - Emergency Stop
GNDv: Connection Vessel GND
S20:
Switch - Main Power ON/OFF
H10:
Lamp - Airfilter Warning Indicator
S30:
Switch - Compressor Load Signal
H20:
Lamp - Element Temperature Shutdown Indicator
S40:
Switch - Compressor Noload Signal
H30:
Lamp - Compressor Loaded Indicator
S50:
Switch - Engine Stop Signal
H40:
Lamp - Ready To Start Indicator
S60:
Switch - Engine Start Signal
H50:
Lamp - Engine Shutdown Indicator / Override Indicator
S70:
Switch - Override Switch
H60:
Lamp - Oiltronix™ Failure Indicator (Option)
S80:
Switch - Draining Acknowledged (Option)
H70:
Lamp - Oiltronix™ Warning Indicator (Option)
TS10: Temperature Switch
H80:
Lamp - Oiltronix™ Draining Indicator (Option)
X1:
Connector
K10:
Relay - Starter Motor Activation
Y10:
Solenoid Valve - Engine Fuel Stop Solenoid
K20:
Relay - Engine Shutdown
LS10: Level Switch - Coolant Level Protection
12/24VDC
+
-
G10
M10
K10
K0
K0
G30
K20
GNDv
K10
S60
S50
PS10
S70
S10
S20
1
2
3
4
5
7
8
9
10
11
12
13
14
15
16
6
X1
K20
H10
H20
S30
H50
Y10
H40
H30
H80
S80
H70
H60
S40
30
87
87a
TS10
LS10
B+
D+
W+
B-
M
Connect to
Compressor Drive GND
+
-
G20
Summary of Contents for ORV 10