- 46 -
5.2.9
Settings
For buttons to be used see “Pc4003™ button
overview”.
5.2.9.1 Set Pressure Setpoint
When in Main View, the following display is shown.
Press the Up/Down arrows to set the requested
pressure.
5.2.9.2 Acknowledge an Alarm
If an alarm becomes active, for example a Low Fuel
Level Warning, press the Enter button to
acknowledge this alarm.
Then, if the fuel level is still low, the view changes to:
As soon as the fuel level is higher than the warning
level again, the alarm icon will automatically
disappear.
As long as there is an alarm icon in the middle of the
bottom part of the view, all active acknowledged / un-
acknowledged alarms can be consulted by pressing
the Alarm View button.
Pressing the Alarm View button again, will bring you
back to the Main View.
5.2.9.3 Set Clock
1. Press the Settings View button.
2. Scroll to the '1000 GENERAL SETTINGS' menu.
3. Press Enter.
4. Scroll to the '1290 DATE/TIME' menu.
5. Enter the Date/Time menu.
6. Scroll to the parameter you want to change.
7. Enter this parameter.
To change the 'RTC Month', scroll to the preferred
month and press Enter.
To change any other RTC setting, the red figure is
editable. Scroll up/down and press enter to
change. Use left/right to shift between editable
figures.
8. Now press BACK until you are back in the Main
View (or in the menu you require).
MAIN VIEW
LOADED - AIR DISCHARGE PRESSURE REGULATION
10.1 bar
1439RPM
1286h
10.1
bar
SET
9.8
bar
40%
MAIN VIEW
LOADED - AIR DISCHARGE PRESSURE REGULATION
9.2
bar
SET
9.0
bar
3000 LOW FUEl LEVEL WARNING
MAIN VIEW
LOADED - AIR DISCHARGE PRESSURE REGULATION
10.1 bar
1439RPM
1286h
9.2
bar
SET
9.0
bar
40%