Technical data
Machine data
PP 100
8311030450
8311030460
8311030420
380 V ± 10%, 50/60 Hz, 17 A
440 V ± 10%, 50/60 Hz, 17 A
525 V ± 10%, 50 Hz, 12 A
Power supply
21 A (< 4 ms)
21 A (< 4 ms)
15 A (< 4 ms)
Peak current
10 (13.4)
Input power, kW (HP)
352 (13.9)
Height, mm (in.)
402 (15.8)
Width, mm (in.)
695 (27.4)
Length, mm (in.)
5 to 40 (41 to 104)
Ambient temperature range, °C (°F)
45 (99)
Weight incl oil, kg (lb)
38 (1.4)
Flow, l/m (ft
3
/min)
20 to 60 (68 to 140)
Hydraulic oil temperature, °C (°F)
120 (1,740)
Nominal pressure, bar (psi)
Helical rotor pump, directly driven from the motor shaft.
Pump type
8.7 (2.3)
Oil tank capacity, litres (US gal)
10 µ filter in return line. Filter by-pass valve.
Filtration
Water
Cooling system
Inverter controled 3 phase PM motor.
Motor type
Supply interrupted or at zero voltage for not more than 3 ms at any random time in the supply
cycle with more than 1 s between successive interruptions.
Voltage interruption limit
Voltage dips not exceeding 20 % of the peak voltage of the supply for more than one cycle
(20ms) with more than 1 s between successive dips.
Voltage dips limit
Transient voltage increase 0,5s repeated < 1time/min: 20 %
Transient voltage increase 3ms repeated < 1time/min: 40 %
Overvoltage limit
PC1 5 pole, 3P, Pilot +E
Socket
Installed with residual current device
Earth supervision
Earth in cable screen
Electrical safety
IP66
IP class
Noise declaration statement
Noise
Declared values
Sound power
Sound pressure
2000/14/EC
EN ISO 11203
Lw
measured dB(A) rel
1pW
Lw
2
guaranteed dB(A) rel
1pW
Lp
1
dB(A) rel
20uPa
Type
87
90
74
PP 100
1
Sound pressure level according to EN ISO 11203 at 1 metre distance.
2
Guaranteed sound power according to EN ISO 3744 in accordance with directive 2000/14/EC inclusive spread
in production.
These declared values were obtained by laboratory type testing in accordance with the stated directive or
standards and are suitable for comparison with the declared values of other tools tested in accordance with
the same directive or standards. These declared values are not adequate for use in risk assessments and
values measured in individual work places may be higher. The actual exposure values and risk of harm
experienced by an individual user are unique and depend upon the way the user works, in what material the
© 2016 Construction Tools PC AB | No. 9800 1364 01c | 2016-04-06
Original instructions
18
PP 100
Safety and operating instructions