Advanced Troubleshooting
The PP100 is equipped with a USB service data interface (A) used for advanced diagnostics. The data interface
is used for download of log files. The files can be used as an aid in fault finding, in case that the normal
troubleshooting described in this manual is not sufficient. The interface can also be used for future software
upgrades.
A
Use a USB memory stick preformatted as FAT16 or FAT32.
NOTICE
The USB memory should not contain any files prior to the first setup.
Connect the USB stick to a PC and open the root folder. Open a text application, preferably Notepad, and
create a text file containing a single row. The row should read “ReadErrorLogC”. Save the file as text with the
name “pcmd.pp”.
NOTICE
The diagnostics tool is case sensitive. Make sure the "ReadErrorLogC" command is spelled correctly
and is using the correct case.
NOTICE
Some text applications will automatically add a suffix ".txt" to the file name. Make sure that the file
is named "pcmd.pp" and not "pcmd.pp.txt".
Service data download
1. Put the PP100 in standby mode.
2. Insert the USB stick containing the command file.
3. LED 1-3 will start to flash. The data transfer will take less than 30 seconds. All LEDs will light continuously
when the data transfer is complete.
4. Remove the USB stick.
The USB stick contains a newly created folder. The folder will have the same name as the serial number of the
machine. The folder contains 2 files called “Deviceinfo.txt” and “Errorlog.txt”.