Remedy
Description
Error text
Error log
no.
Cool down for 15 minutes, use
cooling water flow.
High motor temp, PP100 to standby.
ERR _WINDING_HIGH_TEMP_MAJOR
38
Cool down for 15 minutes, use
cooling water flow.
High motor temp, PP100 to standby.
ERR _ROTOR_HIGH_TEMP_MAJOR
39
Cool down for 15 minutes, use
cooling water flow.
High motor temp, PP100 to standby.
ERR _DRIVER_HIGH_TEMP_MAJOR
40
Top up hydraulic oil.
Low oil volume, PP100 to standby.
ERR_OIL_LOW_LEVEL_MAJOR
50
Check water supply. Cool down for
30 minutes. Repeated indication,
service is needed. Contact nearest
authorised workshop.
High oil temp, PP100 to standby.
ERR_TOO_HIGH_OIL_TEMP
51
Check water supply. Water pressure
needs to be above 4 Bar.
Incoming water pressure low.
ERR_LOW_WATER_PRESSURE
53
-
Incoming water pressure restored.
INFO_WATER_PRESSURE_RESTORED
54
The error messages can also be used to determine if the media supply is working as expected. The timestamp
will aid in finding during what time the electrical or water supply to the machine was insufficient or faulty.
Check electrical supply
Error no. 0,4,5,7
Power supply
Insufficient cooling or too low water pressure.
Check water supply.
Error no. 35-40, 51 and 53
Water supply
The time stamp for each error in the log file is GMT. The clock will not need to be adjusted, nor should battery
replacement be needed, during the lifetime of the machine.
23
© 2016 Construction Tools PC AB | No. 9800 1364 01c | 2016-04-06
Original instructions
Safety and operating instructions
PP 100