General information
EC DECLARATION OF CONFORMITY
We, Atlas Copco Tools AB, S-105 23 STOCK-
HOLM SWEDEN declare under our sole responsib-
ility that our product (with type and serial number,
see front page) and in combination with our accessor-
ies, to which this declaration relates is in conformity
with the appropriate standard(s):
EN 792-4
and in accordance with the following directive(s):
98/37/EEC
Stockholm, October 2006
Lennart Remnebäck, General Manager
Signature of issuer
Installation
Air quality
• For optimum performance and maximum machine
life we recommend use of compressed air with a
dew point b2°C and +10°C. Installation
of an Atlas Copco refrigeration-type air dryer is
recommended.
• Use a separate air filter of type Atlas Copco FIL,
removes solid particles larger than 15 microns and
more than 90 % of liquid water, installed as close
as possible to the machine and prior to any other
air preparation unit like REG or DIM (please see
Air Line Accessories in our main catalogue). Blow
out the hose before connecting.
Models which need air lubrication:
• The compressed air must contain a small quantity
of oil. We strongly recommend that you install an
Atlas Copco oil-fog lubricator DIM, to be set
normally at 3-4 drops/min (50mm
3
/m
3
) for long
cycle running tools, or an Atlas Copco single-point
lubricator type Dosol for short cycle running tools.
For Dosol setting please see Air Line Accessories
in our main catalogue.
Lubrication-free models:
• Regarding lubrication free tools it is, at the cus-
tomers option, no disadvantage if the compressed
air contains a small quantity of oil as supplied
from a lubricator DIM or Dosol.
An exception is turbine tools that should be kept
oil free.
Compressed air connection
• The machine is designed for a working pressure
(e) of 6–7 bar = 600–700 kPa = 87–102 psi.
• Blow out the hose before connecting.
Maintenance
Maintenance
Lubricate the machine regularly with air tool oil.
If the machine is used every day, it should be
overhauled and cleaned once every six months.
The use of other than genuine Atlas Copco replace-
ment parts may result in decreased tool performance
and increased maintenance and may, at the option
of the company, invalidate all warranties.
Cleaning
At 100 hour operating intervals or earlier if operation
becomes sluggish or the machine shows sign of
sticking, flush through with paraffin or a similar
material. Immediately after flushing thoroughly oil
the machine with air tool oil.
Grease guide
Air lubrication
Grease
Brand
Energol E46
Energrease LS-EP2
BP
Arox EP46
Beacon EP2
Esso
Chopin 46
Rembrandt EP2
Q8
Almo Oil 525
Mobilegrease XHP 222
Mobil
Torcula 32
Alvania EP2
Shell
Aries 32
Multifak EP2
Texaco
BR2 Plus
Molycote
Useful information
You can find all kind of information concerning Pro
products, accessories, spare parts, published matters
on our WEB site!
C
Log in to www.pro-powertools.com
Technical data
Noise and vibration emission
dB(A)
Noise (according to ISO 15744)
103 (tem-
porary)
Measured sound pressure level
114 (tem-
porary)
Determined sound power level
3
Spread in method and production
5
Atlas Copco Tools - 9836 3979 00
Safety and operating instructions
P2535-H