QMC41-50-HM4
EN
Service
© Atlas Copco Industrial Technique AB - 9836 9800 01
11
Service
Preventing ESD Problems
The components inside the tool and controller are sensitive to electrostatic discharge. To avoid future mal-
function, make sure that service and maintenance is carried out in an ESD approved work environment.
The figure below shows an example of an appropriate service work station.
Maintenance Instructions
Service Recommendations
Preventive maintenance is recommended at regular intervals. See the detailed information on preventive
maintenance. If the product is not working properly, take it out of service and inspect it.
If no detailed information about preventive maintenance is included, follow these general guide-
lines:
■
Clean appropriate parts accurately
■
Replace any defective or worn parts
Preventive maintenance
Recommended interval between actions:
Valid at normal usage of the tool at a load up to 70% of maximum torque.
Service should only be carried out by trained technician following provided service instructions and
using original Atlas Copco spare parts.
Interval
Action
1.500.000 cycles or 1 year
Calibrate the tool
1.500.000 cycles
Exchange bit grounding
3.000.000 cycles
Exchange front part
3.000.000 cycles
Exchange motor
Instructions
Service equipment:
■
Normal workshop equipment.
■
Necessary special equipment as shown in the exploded views/tables.
■
For testing a calibration rig is recommended.
■
PC with internet connection to be able to download necessary keys.