As long as the element is stopped, an hourglass icon (1) replaces the element concerned in the
main screen:
Element 2 is stopped during a Minimum Stop Time due to a high element temperature
If the element temperature exceeds the factory set shutdown warning repeatedly, the element will
shut down, alarm LED (4) (see section
Control panel
) will lit and following screen will appear:
Element 2 is shutdown due to repeatedly high element temperature warnings
If this occurs:
1. Switch off the voltage and remedy the problem cause.
2. Switch on the voltage and reset the element manually by selecting the warning icon (or go to
warning menu - elements) and press Reset:
Warning element screen (element 2 is triggered)
Instruction book
36