Text on image
(1)
Regulation
(2)
Stopping pressure
• The upper and lower limit of the setting is shown in grey, the actual setting is shown in black.
Use the ↑ or ↓ key of the Scroll keys to modify the settings as required and press the Enter
key to accept.
If necessary, change the other settings as required in the same way as described above.
3.14 Event history menu
Menu icon, Event History
Function
To call up the last shutdown and last emergency stop data.
Procedure
Starting from the
Main screen
,
• Using the Scroll keys, move the cursor to the action button Menu and press the Enter key.
Following screen appears:
Text on image
(1)
Menu
(2)
Regulation
• Using the Scroll keys, move the cursor to the Event History icon (see above).
• Press the Enter key. The list of last shutdown and emergency stop cases is shown.
Instruction book
2920 7140 52
51
Summary of Contents for SF 15+
Page 1: ...INSTRUCTION BOOK OIL FREE SCROLL COMPRESSORS SF 15 SF 17 SF 22 SFD 11 SFD 15 SFD 22 ...
Page 2: ......
Page 16: ...2 2 Flow diagram Flow diagram of SF 15 SF 17 SF 22 Instruction book 14 2920 7140 52 ...
Page 18: ...Flow diagram of SFD 11 SFD 15 SFD 22 Instruction book 16 2920 7140 52 ...
Page 112: ......
Page 113: ......