Period
(note 1)
Running
hours (note
1)
Service Plan
Operation
Every 4
years
10000
B
8 bar and 116 psi compressors:
• Replace the element outlet pipe and the plastic insert.
See section
Outlet pipe replacement
(3.7 kW elements
only).
Note: from S/N API 772 000 onwards, a new type of 3.7
kW compressor element is used. This new element does
no longer have a plastic insert in the outlet pipe and
replacement is no longer required.
• Clean fan (ref 124 on
Flow diagram
), fan duct and
element cooling fins (see note 2). See section
Cleaning
cooling fins
.
• Have orbiting scroll bearing and pin crank bearings
greased (see note 3).
• Replace tip seals and dust seal.
• Replace inlet seal.
Notes:
1. Maintenance must be done according the number of running hours
or
according the running
period, whichever comes first.
2. More frequently in a dusty environment.
3.
Important note:
Regreasing of the bearings of the compressor element must be done with
special grease
, a
special grease gun
and according a
specific procedure
.
In high ambient conditions, the bearings must be greased more frequently: for every 5 °C (9
°F) increase above 30 °C (86 °F), the maintenance interval should be reduced with 30 %.
Contact your supplier for details.
Check more frequently if operating in a dusty atmosphere. Check for cleanness and
damage. Replace a dirty or damaged filter by a new one.
4. In extremely dry conditions (relative humidity below 15 %), the tip seals and dust seals need
to be replaced more frequently.
6.2
Service kits
Service kits
For overhauling and for preventive maintenance, a wide range of service kits is available. Service
kits comprise all parts required for servicing the component and offer the benefits of genuine
parts while keeping the maintenance budget low.
Consult the Spare Parts List for part numbers.
6.3
Disposal of used material
Used filters or any other used material (e.g. desiccant, lubricants, cleaning rags, machine parts,
etc.) must be disposed of in an environmentally friendly and safe manner, and in line with the
local recommendations and environmental legislation.
Instruction book
86
2920 7140 52
Summary of Contents for SF 15+
Page 1: ...INSTRUCTION BOOK OIL FREE SCROLL COMPRESSORS SF 15 SF 17 SF 22 SFD 11 SFD 15 SFD 22 ...
Page 2: ......
Page 16: ...2 2 Flow diagram Flow diagram of SF 15 SF 17 SF 22 Instruction book 14 2920 7140 52 ...
Page 18: ...Flow diagram of SFD 11 SFD 15 SFD 22 Instruction book 16 2920 7140 52 ...
Page 112: ......
Page 113: ......