- 97 -
COMPRESSOR / ENGINE SPECIFICATIONS
REFERENCE CONDITIONS
The inlet conditions are specified at the air inlet grating outside the canopy.
LIMITATIONS
Designation
XAMS 527 - XAMS 1150
XATS 487 - XATS 1050
XAHS 447 - XAHS 950
XAVS 407 - XAVS 900
Absolute inlet pressure
bar(e)
1
1
1
1
psi
14.5
14.5
14.5
14.5
Relative air humidity
%
0
0
0
0
Air inlet temperature
°C
20
20
20
20
°F
68
68
68
68
Nominal effective working pressure
bar(e)
8.6
10.3
12
14
psi
125
149
174
203
Designation
XAMS 527 - XAMS 1150
XATS 487 - XATS 1050
XAHS 447 - XAHS 950
XAVS 407 - XAVS 900
Minimum effective receiver pressure
bar(e)
4
4
4
4
psi
58
58
58
58
Maximum effective receiver pressure, compressor
unloaded
bar(e)
10
11.7
13.4
13.4
psi
145
170
194
194
Maximum ambient
temperature at sea level
without aftercooler
°C
50
50
50
50
°F
122
122
122
122
with aftercooler
°C
45
45
45
45
°F
113
113
113
113
Minimum starting temperature
°C
-10
-10
-10
-10
°F
14
14
14
14
Minimum starting temperature, with coldstart
equipment
°C
-25
-25
-25
-25
°F
-13
-13
-13
-13
Altitude capability
see separate curve on page 100
Summary of Contents for XAHS 447 Cd S3A APP
Page 2: ......
Page 24: ... 24 SH 03 ENGINE CIRCUIT 1 2 3 5 9 8 7 6 G 4 10 A B C D E F 9822 0963 49 ...
Page 25: ... 25 SH 04 CONTROL MODULE 1 2 3 5 9 8 7 6 4 10 A B C D 9822 0963 49 ...
Page 26: ... 26 SH 05 COMPRESSOR CIRCUIT 1 2 3 5 9 8 7 6 G 4 10 A B C D E F 9822 0963 49 ...
Page 27: ... 27 SH 06 OPTIONAL EQUIPMENT 1 2 3 5 9 8 7 6 G 4 10 A B C D E F 9822 0963 49 ...
Page 28: ... 28 SH 07 OPTIONAL EQUIPMENT 1 2 3 5 9 8 7 6 4 10 A B C D E 9822 0963 49 ...
Page 110: ... 110 Notes ...
Page 111: ......
Page 112: ......