Instruction Manual
1092 0381 48
37
3.
2
.
1
Specific start procedure
Follow this start procedure when the compressor is put in operation for the first time and after running out of fuel or
changing the fuel filter.
Fuel prefilter
•
Operate the hand pump (1) at the prefilter until it is under pressure.
•
Switch the “OFF/ON” switch to position ”ON”. The instrument panel will now perform a brief selftest.
•
Push the start button and the starter motor will automatically try to start the engine..
After cleaning /draining the fuel tanks, the system is filled with air.
Before starting the engine operate the fuelpump on the fuelfilter to fill the fuelsystem.
Operate the pump until (1) the system is under pressure.
When under pressure the engine will start after approximately 10 seconds. If the system is
not under pressure, it will take a few minutes untill the engine will start.