Instruction Manual
52
1092 0381 48
3.3.9
Power off
Switch the controller off by switching the Power switch to the position “OFF”.
The compressor is equipped with a battery switch.
When the compressor is not in use, this switch must always be in the “OFF” position.
It is not allowed to use this switch as an emergency switch or for stopping the compressor.
It can damage the controller or the engine’s Electronic Control Unit when using the battery switch for
stopping.
Always first shut off the controller and wait until the display is dark before switching the battery switch to
position “OFF”.Diesel Particulate Filter Regeneration
3.3.10
DIESEL PARTICULATE FILTER REGENERATION
When the Diesel Particle Filter regeneration process is kept at its default ‘AUTOMATIC’ setting, then the
DPF regeneration will be performed automatically when the Soot Load exceeds 60%.
The controller display will indicate an ongoing DPF Regeneration by showing the HEST icon (High
Exhaust System Temperature):
Active Buttons
Measurement View Button
Settings View Button
Alarms View Button
Enter Button
(to acknowledge the shown alarm)
MAIN VIEW
SHUTDOWN
0.0
2000 EMERGENCY STOP
HEST Icon