XAHS365 Md
24
14. Air and oil mist expelled
from air filters
immediately after
stopping.
a. Check valve at element outlet leaking or
a. Remove and inspect. Replace valve if
necessary. Replace air filter elements and
safety cartridges. Check the oil level and add
oil if necessary. Run the compressor for a few
minutes, stop and recheck oil level.
b. Plunger of oil stop valve jammed.
b. See a.
15. Compressor overheating.
a. Insufficient compressor cooling.
a. Locate compressor away from walls; when
banked with other compressors, leave space
between them.
b. Oil cooler clogged externally.
b. Clean oil cooler.
c. Oil cooler clogged internally.
c. Consult Atlas Copco.
d. Replace filters.
e. Oil level too low.
e. Check oil level. Top up level, if necessary.
f. Thermostatic by-pass valve remains stuck in
f. Remove and check for proper opening and
closing. Replace if out of order.
g. Check and correct as necessary.
h. Oil stop valve malfunctioning.
h. Remove and inspect valve.
i. Oil separator element clogged.
i. See 9c.
Problem
Possible faults
Corrective actions
Summary of Contents for XAHS365 Md
Page 2: ...XAHS365 Md 2 ...
Page 38: ......
Page 39: ...Printed in Belgium 10 2000 2927 1233 03 ...
Page 40: ...Instruction Manual for Portable Compressors XAHS365 Md ...