- 33 -
Before starting open the air outlet valve(s) (see
section
, AOV) and
push circuit breaker button (F1) once (open hood
first). Circuit breaker button should now be in
position B.
The control panel indicates receiver
pressure (PG) and accumulated
operating hours (P1).
The circuit breaker button is a
protection against unintended starting
of the compressor.
A
B
(F1)
Starting procedure
1. To start, turn start switch S1 clockwise to position
1, lamp H2 (general alarm lamp) will go on.
2. Check correct operation of alarm lamps H1 and
H2 by pushing lamp test button S4. Both alarm
lamps (red) should go on.
3. Turn start switch S1 further clockwise into
position 3.
The starter motor will set the engine in motion.
The maximum allowed starter time, where the
starter motor is running continuously is 20
seconds.
If the engine does not catch, a new attempt can be
made after 30 seconds waiting.
The temperature alarm lamp H1 and the general
alarm lamp H2 will go out as soon as the engine
has been started.
4. The start switch automatically springs back to
position 1.
Lamp H1 only will go on when the compressor
outlet temperature is too high.
5. Close the air outlet valve(s) (AOV).