- 37 -
(continuation of page 36)
Notes
1. More frequently when operating in a dusty environment.
2. Replace the element after 1000 running hours or when the pressure drop exceeds 0.8 bar (11.6 psi).
3. Refer to the Deutz operation manual.
4. 500 hours only valid when using PAROIL SAE 15W40.
5. Also drain engine oil from engine oil cooler (see chapter
,
DPec = Drain plug engine oil cooler).
6. In case of poor fuel quality, replace fuel filter more frequently.
7. The valves need to be adjusted for the first time before 500 running hours.
8. Option, additional fuel filter: heavy duty filter element 2914 8092 00, to be ordered separately.
Keep the bolts of the housing, the lifting
eye, the towbar and the axle securely
tightened.
Refer to section Technical specifications
and section Height adjustment for the
torque values.
Summary of Contents for XAS 185 DD7
Page 2: ......
Page 22: ... 20 CONTINUOUS REGULATING SYSTEM UV UA VH RV SR AR CE ...
Page 67: ......