- 77 -
Adjustments and servicing procedures
ADJUSTMENT OF THE CONTINUOUS PNEUMATIC REGULATING SYSTEM
The working pressure is determined by the tension of
the spring in the regulating valve (1). This tension can
be increased to raise the pressure and decreased to
lower it by turning the adjusting wheel clockwise and
anti-clockwise respectively.
To adjust the normal working pressure, proceed as
follows:
1. Loosen the lock nut of the regulating valve.
2. Release Regulating Valve (turn out).
3. With the outlet valves (2) closed, adjust the
regulating valve (1), until a pressure is reached of
nominal pr 2 bar (+ 29 psi).
4. Lock the regulating valve (1) by fixing the lock
nut.
(1)
(2)
Summary of Contents for XRHS 1150 CD4 C3 WUX
Page 2: ......
Page 16: ... 16 Main parts ...
Page 18: ... 18 REGULATING SYSTEM ...
Page 21: ... 21 ELECTRIC SYSTEM 9822 0963 40 C13 HP ...
Page 105: ......
Page 106: ...www atlascopco com ...