- 94 -
COMPRESSOR / ENGINE SPECIFICATIONS
REFERENCE CONDITIONS
The inlet conditions are specified at the air inlet grating outside the canopy.
LIMITATIONS
Designation
XRHS 527 Cd - XRHS 1150 CD6
XRVS 487 Cd - XRVS 1050 CD6
Absolute inlet pressure
bar(e)
1
1
psi
14.5
14.5
Relative air humidity
%
0
0
Air inlet temperature
°C
20
20
°F
68
68
Nominal effective working pressure
bar(e)
20
25
psi
290
363
Designation
XRHS 527 Cd - XRHS 1150 CD6
XRVS 487 Cd - XRVS 1050 CD6
Minimum effective receiver pressure
bar(e)
12.5
15.5
psi
181
225
Maximum effective receiver pressure, compressor
unloaded
bar(e)
22
27
psi
319
392
Maximum ambient temperature
at sea level
°C
45
45
°F
113
113
Minimum starting temperature
°C
-10
-10
°F
14
14
Minimum starting temperature, with coldstart
equipment
°C
-25
-25
°F
-13
-13
Altitude capability
see separate curve on page 97