- 44 -
After cooling down the engine will stop and the
display will show
The engine is stopped, and the controller will do a
double check to see if the engine is really stopped.
SHUTDOWN
When the machine is shutdown due to a critical alarm
or an emergency stop the display will show
POWER OFF
Switch the controller off by switching the Power
switch to the position “OFF”.
The compressor is equipped with a battery switch.
When the compressor is not in use, this switch must
always be in the “OFF” position.
It is not allowed to use this switch as an emergency
switch or for stopping the compressor.
It can damage the controller or the engine’s
Electronic Control Unit when using the battery switch
for stopping.
Always first shut off the controller and wait until the
display is dark before switching the battery switch to
position “OFF”.Diesel Particulate Filter
Regeneration
DIESEL PARTICULATE FILTER
REGENERATION
When the Diesel Particle Filter regeneration process
is kept at its default ‘AUTOMATIC’ setting, then the
DPF regeneration will be performed automatically
when the Soot Load exceeds 60%.
The controller display will indicate an ongoing DPF
Regeneration by showing the HEST icon (High
Exhaust System Temperature):
Active Buttons
Start Button
(to initiate Start command)
Measurement View Button
Settings View Button
Alarms View Button
MAIN VIEW
ENGINE STOPPING
--RPM
5.3bar
41%
1286h
Active Buttons
Measurement View Button
Settings View Button
Alarms View Button
Enter Button
(to acknowledge the shown alarm)
MAIN VIEW
SHUTDOWN
0.0
2000 EMERGENCY STOP