- 46 -
INHIBIT DPF REGENERATION
When running in an environment where an elevated
exhaust temperature is not allowed, it might be
necessary to inhibit DPF regeneration. This has to be
done at Service Level. The controller has now put the
DPF Regeneration in a FORCED OFF mode, which is
Inhibit DPF Regeneration.
The compressor controller will communicate with the
engine controller and the (RED) Inhibit DPF
regeneration icon will appear:
When the controller gets powered down, it will (at
next power up) fall back to its default settings,
meaning AUTOMATIC DPF regeneration.
INCREASING SOOT LOAD
When the DPF Regeneration is Inhibited, or when the
engine does not get sufficient possibility to
automatically perform a full DPF Regeneration, the
Soot Load will exceed the normal levels.
The controller will show the DPF Regeneration
Needed Icon. In case of Inhibited DPF Regeneration,
the DPF Regeneration Needed Icon will overwrite the
DPF Inhibited Icon.
Required Action:
•
Force DPF Regeneration, see paragraph
FORCE
DPF REGENERATION
When DPF Regeneration is started, the DPF
Regeneration Needed icon will disappear and the
HEST icon will pop-up.
SOOT LOAD reaches 90% (only when DPF
Regeneration is Inhibited)
When still no DPF regeneration is forced the next
warning alarm will pop-up:
Required Action:
•
Acknowledge the ‘PLEASE FORCE DPF
REGENERATION !’ warning (press Enter while
in the Main View).
•
Force DPF Regeneration, see paragraph
FORCE
DPF REGENERATION
When DPF Regeneration is started, the DPF
Regeneration Needed icon will disappear and the
HEST icon will pop-up.
DPF Regeneration Inhibited
MAIN VIEW
READING ENGINE DATA
0.0
--RPM
0.0bar
41%
1286h
DPF Regeneration needed
MAIN VIEW
LOADED
18.6
1424RPM
18.6bar
41%
1286h
DPF Regeneration needed
MAIN VIEW
LOADED
18.6
7130 PLEASE FORCE DPF REGENERATION !