- 62 -
OIL AND OIL FILTER CHANGE
ENGINE OIL AND OIL FILTER CHANGE
See section Preventive maintenance schedule for
the compressor.
TOPPING UP THE COMPRESSOR OIL
1. Stop the compressor. Wait a few minutes until the
pressure is released through the automatic blow-
down valve. Make sure that all pressure is
released by loosening the filler plug (1) one turn.
2. Wait a few minutes until the oil level is constant.
3. Remove the filler plug (1) and top up with oil until
the pointer of the oil level gauge (2) is in the upper
part of the green area.
4. Reinstall and tighten the filler plug (1).
COMPRESSOR OIL AND OIL FILTER
CHANGE
The quality and the temperature of the oil determine
the oil change interval.
The prescribed interval is based on normal operating
conditions and an oil temperature of up to 100 °C
(212 °F) (see section Preventive maintenance
schedule for the compressor).
When operating in high ambient temperatures, in very
dusty or high humidity conditions, it is recommended
to change the oil more frequently.
(2)
(1)
In this case, contact Atlas Copco.
(4)
(3)
(1)
(2)
Summary of Contents for XRVS 1300 CD7
Page 2: ......
Page 20: ... 20 PNEUMATIC REGULATING SYSTEM AR RV CEhp CElp BOV TV UA ...
Page 95: ...Dataplate 95 ...
Page 100: ... 100 ...
Page 101: ......
Page 102: ......