- 88 -
COMPRESSOR / ENGINE SPECIFICATIONS
REFERENCE CONDITIONS
The inlet conditions are specified at the air inlet grating outside the canopy.
LIMITATIONS
Designation
XRXS 567 Cd - XRXS 1240 CD7
XRXS 607 Cd - XRXS 1275 CD7
XRVS 617 Cd - XRVS 1300 CD7
XRVS 647 Cd - XRVS 1350 CD7
Absolute inlet pressure
bar(e)
1
1
psi
14.5
14.5
Relative air humidity
%
0
0
Air inlet temperature
°C
20
20
°F
68
68
Nominal effective working pressure
bar(e)
30
25
psi
435
363
Designation
XRXS 567 Cd - XRXS 1240 CD7
XRXS 607 Cd - XRXS 1275 CD7
XRVS 617 Cd - XRVS 1300 CD7
XRVS 647 Cd - XRVS 1350 CD7
Minimum effective receiver pressure
bar(e)
19
16
psi
276
232
Maximum effective receiver pressure, compressor
unloaded
bar(e)
32
27
psi
464
392
Maximum ambient temperature
at sea level
without
aftercooler
°C
50
50
°F
122
122
with
aftercooler
°C
45
45
°F
113
113
Minimum starting temperature
°C
-10
-10
°F
14
14
Minimum starting temperature, with coldstart
equipment
°C
-25
-25
°F
-13
-13
Altitude capability
see separate curve on page 91
Summary of Contents for XRVS 1300 CD7
Page 2: ......
Page 20: ... 20 PNEUMATIC REGULATING SYSTEM AR RV CEhp CElp BOV TV UA ...
Page 95: ...Dataplate 95 ...
Page 100: ... 100 ...
Page 101: ......
Page 102: ......