- 70 -
FORCE DPF REGENERATION
If DPF Regeneration is Inhibited
Machine is not running:
Power the controller down. At next power up, the
DPF Regeneration settings will be back to default,
and an Automatic DPF Regeneration will take place
at the soonest appropriate moment.
Machine is running:
•
Press the Settings View Button
•
Enter the ‘1000 GENERAL SETTINGS’ menu
•
Scroll one line down and Enter the ‘1140 ECU
DPF REGENERATION’ menu
OR
•
Scroll down and Enter the ‘MODE’ parameter
•
Scroll down and Enter the ‘AUTOMATIC’ setting
•
Press the Back button 3 times to get back to the
Main View
DPF Regeneration setting will now be AUTOMATIC
DPF REGENERATION.
Customer Level can now select between AUTO
Regeneration & INHIBIT Regeneration, as long as
the controller is not powered down (after power
down, it will fall back to its default DPF Regeneration
settings, and a Service Level is needed to go back to
Inhibit DPF Regeneration).