Start-up
Electric cabinet of compressor with starter
1. Check that the voltage selecting wires on transformer T1 are connected correctly. An
instruction label is provided.
2. Check that the electrical installation meets local regulations.
3. On compressors with a starter, check the overload relay setting (F21) and check that the
relay is set for automatic resetting.
See
.
Switch on the voltage.
4. Check that the gear casing is filled with oil.
5. Start the motor and stop it immediately.
6. Check that the direction of rotation is correct (as indicated by the arrow): anti-clockwise
looking at the motor drive shaft (there may also be an arrow on the coupling housing). A
grating through which the coupling can be observed is fitted. If the direction of rotation is
wrong, switch off the voltage and reverse two electric inlet connections.
7. Run the compressor for a few minutes.
8. Stop the compressor and check the oil level.
On ZR/ZT 110 up to ZR/ZT 275, the oil level after stopping must be in the middle of the
sight-glass (in the case of longer standstill, the oil level in the sight-glass may increase).
Top up, if necessary, with the correct type of oil.
Instruction book
78
AIF999999