Supply voltage
(V)
Recommended overload setting F21
(A)
460
209
ZR/ZT 200 compressors designed for a maximum inlet temperature of 40 ˚C/104 ˚F with IE3
motor
Supply voltage
(V)
Recommended overload setting F21
(A)
460
197
9.4
Reference conditions
Absolute inlet pressure
14.5 psi(a)
Ambient temperature
68 °F
Air inlet temperature
68 °F
Effective working pressure
102 psi(g) for 102/109/125 psi compressors
Temperature of cooling medium (water or air) inlet
68 °F
Temperature rise of cooling water of ZR Pack
compressors
27 °F
ZR / ZT 160-275
Motor shaft speed for 60 Hz fixed speed compressors
(rpm)
1780
9.5
Limitations
Minimum - maximum ambient temperature (for
standard compressors)
32- 104 °F
Minimum - maximum temperature of air inlet (for
standard compressors)
32- 104 °F
Maximum altitude
3281 ft
Minimum temperature of cooling medium (water or
air) inlet
32 °F
Maximum temperature of cooling air inlet (for
standard compressors)
104 °F
Maximum temperature of cooling water inlet - open
circuit
104 °F
Maximum temperature of cooling water outlet
122 °F
Maximum rise of cooling water temperature (for
compressors without Energy Recovery)
up to 63 °F
Maximum pressure of cooling water inlet
145 psi(g)
Minimum - maximum oil pressure
17.4–65.3 psi(g)