Reference
Name
AS
Silencer
BV
By-pass valve
Ca
Aftercooler
Ci
Intercooler
Co
Oil cooler
CV
Check valve
Eh
High-pressure compressor element
El
Low-pressure compressor element
MTa
Moisture trap, aftercooler
MTi
Moisture trap, intercooler
OF
Oil filter
OP
Oil pump
Description
Oil is circulated by pump (OP) from the sump of the gear casing through cooler (Co).
The oil passes through oil filter (OF) towards the bearings and timing gears.
By-pass valve (BV) opens if the oil pressure should rise above a given value.
2.6
Regulating system
General
The regulator keeps the net pressure within programmable pressure limits by automatically
loading and unloading the compressor depending on the air consumption.