6
Maintenance
6.1
Preventive maintenance schedule
Safety precautions
• Before starting any maintenance or repairs, stop the compressor.
• Depressurize the air system as follows:
• Close the air outlet valve.
• Press the emergency stop button.
• On compressors equipped with Electronic Water Drains (EWD), press the
test buttons on top of the electronic water drains.
• Open the isolating switch (customer's installation) to switch off the voltage to the
compressor, and lock it (Lock Out - Tag Out procedure, LOTO).
• Repairs inside the speed regulation cabinet must only be carried out by Atlas
Copco.
• Wait at least 6 minutes before starting any electrical repairs as hazardous high
voltage remains on the condensers of the variable speed drive for 6 minutes after
switching off the voltage.
• The operator must apply all relevant safety precautions.
Service agreements
Atlas Copco Customer Centers have a range of service agreements to suit your needs:
• An Inspection plan
• A Preventive maintenance plan
• A Total responsibility plan
Contact your Customer Center to agree on a tailor-made service agreement. It will ensure
optimum operational efficiency, minimize downtime and reduce the total life cycle costs and
ensure that all warranties are validated.
Warranty-Product Liability
Use only authorized parts at the correct intervals (check with your local Atlas Copco Service
center). Any damage or malfunction caused by the use of unauthorized parts or unqualified
personnel is not covered by Warranty or Product Liability. In the event of any extended warranty,
the end user must ensure that all required maintenance actions are performed when indicated on
the Elektronikon display (see table below) or, alternatively, use an Atlas Copco Service
agreement.
Service kits
Atlas Copco Customer Centers will be glad to provide you with a wide range of
.
Service kits comprise all parts needed for servicing components and offer the benefits of genuine
Atlas Copco parts while keeping the maintenance budget low.
Regular checks
The following checks should be carried out regularly to ensure safe operation and long service
life. Depending on the environmental and working conditions of the compressor, the local Atlas