Main components
Ref
Name
AF
Air filter
BV
By-pass valve, oil cooler
Ca1
Pre-aftercooler
Ca2
Aftercooler
Ci
Intercooler
Co
Oil cooler
Eh
High-pressure compressor element
El
Low-pressure compressor element
EWDa
Electronic water drain, aftercooler
EWDi
Electronic water drain, intercooler
FC
Oil filler cap
FN
Cooling fan
M1
Drive motor
M25
Fan motor
MTi
Moisture trap, intercooler
SVh
High-pressure safety valve
SVl
Low-pressure safety valve
TV
Load/no-load valve
Y1
Loading solenoid valve
Connections
ANSI flanges
Motor temperature protection
Thermistors are embedded in the windings of the drive motor to warn the operator if the temperature becomes
too high and to shut down the compressor, thereby protecting the motor from overheating.
Anti-condensation heaters
Electric heaters are installed in the motor windings and connected to the compressor cubicle. When the
compressor is stopped, the heaters are automatically switched on. The heaters in the motor will prevent
condensation during stand-still.